FCS-930/960
Ground Loop Control
Powering Up
4.5 Ground Loop
Control
Strict adherence to the wiring conventions noted above within a fully
balanced signal system will yield the best possible results with none of
the problems normally associated with interconnected audio equipment.
Wherever possible, cable screens should not be connected to any signal
pin, but rather left to perform a cable shielding function only.
Where it is not possible to control all of the external cabling, it might
become necessary to have the internal electronic ground of your unit
separated from the case safety ground. Provision is made internally
within the FCS-930/960 to separate these two grounds at a convenient
point, or to add a suitable impedance network as part of a house system
requirement.
Please refer to a later section for information on this procedure.6.
Under no circumstances should the safety ground wire be removed
from the mains AC power connector as an interim measure to achieve
similar results.
When the FCS-930/960 is switched on by operating the power on-off
switch located on the rear panel, the front panel LED showing the
normal MODE will be illuminated. This indicates to you that the internal
power supply circuitry is functioning correctly. The unit will also be in
it’s bypass mode. Should you subsequently have the EQ IN switch
selected before power up, there will be a slight delay before the bypass
relays operate to allow time for the internal circuitry to settle down. This
ensures a silent power up without danger of causing damage to other
equipment connected to the unit’s outputs.
4.6 Powering Up