The Green and Yellow wire of the mains cord must always be connected to an
installation Safety Earth or Ground. The Earth is essential for personal safety as
well as the correct operation of the system, and is internally connected to all
exposed metal surfaces. Any rack framework into which this unit may be
mounted is assumed to be connected to the same grounding circuit.
The incoming mains power is fused within the FDS-388 by the fuse holder
mounted on the rear panel. Should it be necessary, the fuse must be replaced
by one of the same size and current rating.
20mm T250mA for the 240V setting
20mm T500mA for the 120V setting
It is most important for continued safety that this specification is strictly
adhered to. Spare fuses of the correct rating are supplied with the unit from
new.
It is unlikely that the AC fuse will fail during normal use and caution should be
exercised if it does. The most likely reason at first power up is the incorrect
setting of the mains voltage switch on the rear panel. Alternatively the unit may
have been connected across two lines of a three phase supply. In both of these
cases the internal transient suppressors may have been damaged and will
continue to blow replacement fuses, even if the supply is now correct. The
suppressors will have protected the FDS-388 Omnidrive from damage and
need replacing before the unit can be used again.
Refer to section 22.0; Service section for the replacement procedure.